AVENTICS | Bus Coupler AES/Valve Driver AV, Ethernet POWERLINK | R412018143–BAL–001–AF
Conversion of the Valve System
AES-
D-BC-
PWL
UA
P
Fig. 18: Examples for impermissible configurations
12.5.3

Impermissible configurations

Figure 18 displays the configurations that are not permissible. You may not:
Split a 4x or 3x valve driver board (A)
Mount fewer than four valve positions after the bus coupler (B)
Mount more than 64 valves (128 solenoid coils)
Integrate more than 8 AV-EPs
Integrate more than 32 electrical components.
Some configured components have multiple functions and therefore count as multiple electrical
components.
Table 34:
Number of electrical components per component
Configured component
Valve driver boards, 2x
Valve driver boards, 3x
Valve driver boards, 4x
Pressure regulators
Electrical supply plate
UA-OFF monitoring board
A
A
AES-
D-BC-
PWL
UA
P
P
UA
AES-
D-BC-
PWL
Number of electrical components
1
1
1
3
1
1
UA