Permissible Configurations - Aventics Ethernet POWERLINK Description Du Système Et Notice D'emploi

Coupleur de bus aes / pilote de distributeur av
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 131
AES-
D-BC-
PWL
UA
P
A
Fig. 17: Permissible configurations
AVENTICS | Bus Coupler AES/Valve Driver AV, Ethernet POWERLINK | R412018143–BAL–001–AF
The valve system in Fig. 16 consists of three sections:
Table 33:
Example valve system, consisting of three sections
Section
Components
Section 1
Pneumatic supply plate (30)
Three base plates, 2x (20), and one base plate, 3x (21)
Valve driver boards, 4x (24), 2x (22), and 3x (23)
9 valves (61)
Section 2
Pneumatic supply plate (30)
Four base plates, 2x (20)
Two valve driver boards, 4x (24)
8 valves (61)
AV-EP base plate for single pressure control
AV-EP pressure regulator
Section 3
Electrical supply plate (35)
Two base plates, 2x (20), and one base plate, 3x (21)
Supply plate (38), 4x valve driver board (24) and 3x valve driver board (23)
7 valves (61)
12.5.2

Permissible configurations

P
B
B
C
You can expand the valve system at all points designated with an arrow:
After a pneumatic supply plate (A)
After a valve driver board (B)
At the end of a section (C)
At the end of the valve system (D)
To simplify your documentation and configuration, we recommend that you expand the valve
system on the right end (D).
A
B
Conversion of the Valve System
UA
C
B
119
D

Publicité

Table des Matières
loading

Table des Matières