Aventics Ethernet POWERLINK Description Du Système Et Notice D'emploi page 105

Coupleur de bus aes / pilote de distributeur av
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 131
AVENTICS | Bus Coupler AES/Valve Driver AV, Ethernet POWERLINK | R412018143–BAL–001–AF
Table 25:
14
Designation
UL
15
UA
UL (14)
16
IO/DIAG
S/E
UA (15)
17
L/A 1
L/A 2
18
IO/DIAG (16)
19
S/E (17)
L/A 1 (18)
L/A 2 (19)
1)
At least one of the two LEDs L/A 1 and L/A 2 must be flashing in green. Depending on the data exchange, the flashing may be
so fast that it appears that the LED is flickering.
If the diagnostic run is successful, you may commission the valve system. Otherwise, the errors
must be remedied (see section 13 "Troubleshooting" on page 123).
3. Switch on the compressed air supply.
Commissioning the Valve System with Ethernet POWERLINK
Status of the LEDs on commissioning
Color
State
Green
Illuminated
Green
Illuminated
Green
Illuminated
Green
Illuminated
Green
Flashes quickly
Green
Flashes quickly
Meaning
The electronics supply voltage is greater than the lower
tolerance limit (18 V DC).
Actuator voltage exceeds the lower tolerance limit
(21.6 V DC).
The configuration is OK and the backplane is working
perfectly.
The bus coupler exchanges cyclical data with the
controller.
1)
Connection to Ethernet device on fieldbus connection X7E1
is established and data exchange is taking place.
1)
Connection to Ethernet device on fieldbus connection X7E2
is established and data exchange is taking place.
105

Publicité

Table des Matières
loading

Table des Matières