Table 9:
Calculation of the valve system data lengths
Module number
Module
1
Valve driver board, 4x
2
Valve driver board, 2x
3
Valve driver board, 3x
4
Valve driver board, 4x
5
Pressure regulator
6
Valve driver board, 4x
7
Electrical supply
8
Valve driver board, 4x
9
Valve driver board, 3x
10
Input module (1 byte of user data)
11
Input module (1 byte of user data)
12
Output module (1 byte of user data)
bus coupler
Table 10:
Example assignment of output bytes
Object number
Byte no.
TxPDO 1
1
2
3
4
TxPDO 2
1
2
3
4
TxPDO 3
1
2
3
4
TxPDO 4
1
2
3
4
TxPDO 5
1
2
3
4
TxPDO 6
1
2
3
4
AVENTICS | Bus Coupler AES/Valve Driver AV, Ethernet POWERLINK | R412018143–BAL–001–AF
The data lengths of the bus coupler and the modules are shown in Table 9.
Output data
Tx object 1
Tx object 2
Tx object 3
Tx object 4
Tx object 5
Tx object 6
Tx object 7
Tx object 8
Tx object 9
Total number of Tx objects: 9
Both the input and output objects are mapped to the input and output PDOs in physical sequence.
This cannot be changed. In most masters, however, alias names can be assigned to the data, making
it possible for users to select any desired names for the data.
After the PLC configuration, the output bytes are assigned as shown in Table 10.
1)
Bit 7
Bit 6
Valve 4
Valve 4
Valve 3
Sol. 12
Sol. 14
Sol. 12
Valve 9
Sol. 12
Valve 13
Valve 13
Valve 12
Sol. 12
Sol. 14
Sol. 12
Valve 17
Valve 17
Valve 16
Sol. 12
Sol. 14
Sol. 12
Bit 5
Bit 4
Bit 3
Valve 3
Valve 2
Sol. 14
Sol. 12
Output byte (not used)
Output byte (not used)
Output byte (not used)
Valve 6
Sol. 12
Output byte (not used)
Output byte (not used)
Output byte (not used)
Valve 9
Valve 8
Sol. 14
Sol. 12
Output byte (not used)
Output byte (not used)
Output byte (not used)
Valve 12
Valve 11
Sol. 14
Sol. 12
Output byte (not used)
Output byte (not used)
Output byte (not used)
Pressure regulator set point
Pressure regulator set point
Output byte (not used)
Output byte (not used)
Valve 16
Valve 15
Sol. 14
Sol. 12
Output byte (not used)
Output byte (not used)
Output byte (not used)
PLC Configuration of the Valve System
Input data
Rx object 1
Rx object 2
Rx object 3
2 objects for diagnostic data
(Rx objects 4 and 5)
Total number of Rx objects: 5
Bit 2
Bit 1
Valve 2
Valve 1
Sol. 14
Sol. 12
Valve 6
Valve 5
Sol. 14
Sol. 12
Valve 8
Valve 7
Sol. 14
Sol. 12
Valve 11
Valve 10
Sol. 14
Sol. 12
Valve 15
Valve 14
Sol. 14
Sol. 12
83