Presettings On The Bus Coupler; Opening And Closing The Window - Aventics Ethernet POWERLINK Description Du Système Et Notice D'emploi

Coupleur de bus aes / pilote de distributeur av
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 131
AVENTICS | Bus Coupler AES/Valve Driver AV, Ethernet POWERLINK | R412018143–BAL–001–AF
9

Presettings on the Bus Coupler

Configuration error!
An incorrect valve system configuration can cause malfunctions in and damage to the overall
system.
The configuration may therefore only be carried out by qualified personnel (see section 2.4
"Personnel qualifications" on page 73).
Observe the specifications of the system owner as well as any restrictions resulting from
the overall system.
Observe the documentation of your PLC configuration program.
The following pre-settings must be made using the corresponding tools/aids:
Assigning a unique IP address to the bus coupler (see section 9.2 "Assigning a POWERLINK
address" on page 98)
Setting the parameters for the bus coupler (see section "5.5 Setting the bus coupler parameters"
on page 85)
Setting the parameters for the modules (see section 5.5.2 Setting parameters for the modules
on page 86)
No parameter byte is appended to the output data with Ethernet POWERLINK. The parameters
must always be written via objects. B&R controllers offer objects 0x2010 and 0x21nn for writing
the parameters on start-up under the point "device-specific parameters" so that these can
simply be entered there. This ensures that the parameters are transferred when the device
is started.
9.1

Opening and closing the window

3
25
Defective or improperly positioned seal!
Water may enter the device. The protection class IP65 is no longer guaranteed.
Make sure that the seal below the window (3) is intact and properly positioned.
Make sure that the screw (25) has been securely tightened with the correct torque (0.2 Nm).
1. Loosen the screw (25) on the window (3).
2. Lift up the window.
3. Carry out the settings as described in the next steps.
4. Close the window. Ensure that the seal is positioned correctly.
5. Tighten the screw.
Tightening torque: 0.2 Nm
Presettings on the Bus Coupler
NOTICE
NOTICE