AVENTICS | Bus Coupler AES/Valve Driver AV, Ethernet POWERLINK | R412018143–BAL–001–AF
PLC Configuration of the Valve System
Table 17:
Reading out the diagnostic data of the I/O modules byte by byte with object 0x23nn
Object no.
Sub-object no.
2)
0x23nn
0
1
2
3
4
5
1)
When a sub-object without a diagnostic byte is accessed, the value 0 is returned.
2)
nn = module no. 00 to 2A (hexadecimal), corresponds to 00 to 42 (decimal)
Table 18:
Reading out the diagnostic data of the I/O modules as a string with object 0x33nn
Object no.
Sub-object no.
1)
0x33nn
0
1
1)
nn = module no. 00 to 2A (hexadecimal), corresponds to 00 to 42 (decimal)
To read out the bus coupler data as a string:
Enter the following object data in the "Read SDO" field of the PLC configuration software in object
0x3012.
Table 16:
Reading out bus coupler diagnostic data as a string with object 0x3012
Object no.
Sub-object no.
0x3012
0
1
You can find a description of the diagnostic data for the valve zone in chapters"6 7" starting
on page 92. A description of the diagnostic data for AV-EP pressure regulators can be found
in the operating instructions for AV-EP pressure regulators. The diagnostic data for the I/O zone
is described in the system descriptions of the individual I/O modules.
5.7

Extended diagnostic data of the I/O modules

In addition to group diagnosis, some I/O modules can send extended diagnostic data with a length
of up to 4 bytes to the controller. The total data length can thus be up to 5 bytes:
Byte 1 of the diagnostic data contains the group diagnosis information:
Byte 1 = 0x00: No error has occurred.
Byte 1 = 0x80: An error has occurred.
Bytes 2 to 5 contain the extended diagnostic data of the I/O modules. The extended diagnostic data
can only be accessed acyclically with SDOs.
You can read out the diagnostic data of the I/O modules byte by byte or as a string.
To read out the diagnostic data of the I/O modules byte by byte:
Enter the following object data in the "Read SDO" field of the PLC configuration software in object
0x23nn.
Contents
Highest sub-object no.
Group diagnosis
Extended diagnosis, byte 1 (optional)
Extended diagnosis, byte 2 (optional)
Extended diagnosis, byte 3 (optional)
Extended diagnosis, byte 4 (optional)
To read out the diagnostic data of the I/O modules as a string:
Enter the following object data in the "Read SDO" field of the PLC configuration software in object
0x33nn.
Contents
Highest sub-object no.
Diagnosis of the module (string)
Length between 1 and 5 bytes depending on module type
Contents
Highest sub-object no.
Bus coupler diagnostic bytes (string)
(Length 2 bytes)
1)
Default value
5
The minimum length is 1 byte (group diagnosis).
Additional bytes possible depending on module type.
Default value
1
Default value
1