A suppression speed of "0" de-activates the suppression speed bandwidth.
<2>
The setting range of p1082 is limited to n_max_mot.
<3>
If the drive is not stopped via the input setpoint, but via controlled intervention, the lower hysteresis branch is relevant after a subsequent run-up.
<4>
Not at S150/G130/G150.
<5>
For SERVO, the following applies: Only if the function module "Extended Stop and Retract" is activated (r0108.9 = 1).
<100> For SERVO, the following applies: Only if the function module "Extended setpoint channel" is activated (r0108.8 = 1). For r0108.8 = 0, [3095] applies for the generation of the speed limits.
1
2
DO: SERVO, VECTOR, VECTORGL, VECTORMV, VECTORSL
Setpoint channel - Skip frequency bands and speed limitations
n_skip 3
n_skip 4
0.000...210 000.000 [RPM]
0.000...210 000.000 [RPM]
p1093[D] (0.000)
p1094[D] (0.000)
<1>
<1>
-1
y
w
w
w
w
w
w
<3>
n_skip bandwidth
-210 000.000...0.000 [RPM]
0.000...210 000.000 [RPM]
p1086[D] (-210 000.000)
p1101[D] (0.000)
3
4
n_limit pos
0.000...210 000.000 [RPM]
p1083[D] (210 000.000)
p1085[C]
p1083
(1083)
Maximum speed
0...210 000.000 [RPM]
p1082[D] (n_max_Mot)
<2>
p1051[C]
p1083
(1083)
Extended
retraction
p0888 = 2
n_set n. min_lim
r1112
y
0
ESR speed
x
p0893
1
<5>
p1052[C]
p1086
(1086)
p1088[C]
n_limit neg
p1086
(1086)
<101> To view the pre-assignment of the sampling times in p0115, refer to p0112.