Samsung SINAMICS G130 Mode D'emploi page 1161

Table des Matières

Publicité

Droop input source
n-ctrl I_output
[6040.8]
r1482
M_set before M_suppl
[6060.6]
r1508
M_set total
<5>
[6060.8]
r0079
Statik M_komp Skal
0
-2000.0 ... 2000.0 [%]
p1487[D] (100.0)
Statik M_komp
p1486[C]
(0)
p1492
Enable droop
[2520.3]
r1406.11
<4>
n_ctr setp sum
[3080.8]
r1170
n_set before filt.
r0060
[2701.1]
[2704.1]
n_limit pos eff
[6799.1]
[3050.8]
r1084
n_limit neg eff
[3050.8]
r1087
<1>
Mot moment of inertia ratio
Mot M_inertia
0.00000...100000.00000 [kgm²]
1.000...10000.000
p0342[M] (1.000)
p0341[M] (0.00000)
a at M_ctrl scal
0.0...400.0 [%]
p1499[D] (100.0)
M_set total
r0079
[6060.8]
<1>
= Only for vector control without encoder. <3> Scaling: p1489 = 0.100 - for a rated motor torque of r0333 - results in a speed setpoint reduction of 0.1 x p0311.
<2> Only for p1488 > 0.
1
2
DO: VECTOR
Vector control - Speed setpoint, droop
0...3
<3>
p1488 (0)
Droop scaling
0.000...0.500
p1489[D] (0.050)
<1>
3
2
1
150 ms
+
-
0
n
N
M
N
<2>
0
0
-
+
Mom of inert scal
p1497[C]
(100)
<4> The value is displayed correctly only with r0899.2 = 1 (Operation enabled).
3
4
Droop
Droop n_reduction
r1490
1
Droop enabled
r1407.10
0.00...5000.00 [ms]
[2522.3]
n_set limited
r1407.11
[2522.3]
1 = Sensorless vector control, speed pre-control active
from speed control configuration
n_set limited
r1407.11
[2522.3]
<5> p1488 = 1 Not recommended with active acceleration calculation [6031].
5
6
fp_6030_54_eng.vsd
24.10.11 V04.05.00
p0115[1] (Motor Modules)
Refer to [1020.7]
n_set_filter 1 T
p1416[D] (0.00)
n_set after filter
r0062
0
[6490.7]
1
0
p1400.15
0
1
M_ctrl active
r1407.2
n_prectrl motormod
[6060.3]
7
Function diagram
S120/S150/G130/G150
[6031.1]
Pre-control speed
[6730.1]
[6732.1]
[6733.1]
r1431
[6732.1]
8
- 6030 -