Samsung SINAMICS G130 Mode D'emploi page 1154

Table des Matières

Publicité

Ramp-up time
0.000...999 999.000 s
p1120[D] (10.000)
Up ramp scaling
p1138[C]
(1)
p1122
1 = Bypass ramp-function generator
[2505.3]
r1198.15
Ramp flattening-off
[3080.8]
1 = Enable speed setpoint
p1142
[2501.3]
r0898.6
RFG setpt at input
1
r1119
From the setpoint limiting
[3050.8]
0
0
<1>
p1141
0 = Freeze ramp-function generator
[2501.3]
r0898.5
1 = Internal RFG enable
[2634.4]
0 = Internal fast stop
[2634.4]
Accept RFG set val
p1143[C]
(0)
<1>
For SERVO and VECTOR, the following applies: Inhibited during jogging.
<2>
Not at S150/G130/G150.
<3>
After a 0/1 signal a ramp-up is started again.
<4>
With simultaneous jog 1 and 2 (p1055 = p1056 = 1) the last setpoint
remains effective (Freeze ramp-function generator).
<100> For SERVO, the following applies: Only if the function module
"Extended setpoint channel" is activated (r0108.8 = 1).
<101> To view the pre-assignment of the sampling times in p0115, refer to p0112.
1
2
DO: SERVO, VECTOR, VECTORGL, VECTORMV, VECTORSL
Setpoint channel - Basic ramp-function generator
Ramp-down time
0.000...999 999.000 s
p1121[D] (10.000)
Down ramp scaling
p1138[C]
(1)
0 = Internal fast stop
[2634.4]
0
0
1
T
up
Freeze ramp-function generator
x
Tup
0
p1082
1
x
1
0
-p1082
0
1
y
p1082
-p1082
<4>
RFG setting value
x
+ –
p1144[C]
y
(0)
p1082
n_max
[3050.5]
<2>
[3095.7]
3
4
OFF3 ramp-down time
0.000...600.000 s
p1135[D] (0.000)
0
1
0
0
1
T
dn
Tdn
y
t
p1140
1 = Enable ramp-function generator
[2501.3]
r0898.4
t
RFG acceleration
Tup
Tdn
r1149
Other status bits
1
Ramp-up active
0
Ramp-down active
Threshold for
"Ramp-up/ramp-down active"
0.00...1000.00 RPM
p1148[D] (19.80)
5
6
fp_3060_51_eng.vsd
24.10.11 V04.05.00
p0115[3]
Refer to [1020.7]
<100>
<101>
0
0
n_set_4
[3080.1]
1
<3>
Ramp-function generator, status bits
[3080.5]
7
8
Function diagram
- 3060 -
SINAMICS

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sinamics g150

Table des Matières