Commissioning mode active (p0010 = 95)
Safety Integrated commissioning
p0010 = 95
SI password input
p10061
SI password new
p10062
SI ackn password
p10063
<1> Comparator, see [1021].
<2> Analog signal memory, see [1021].
<3> The target checksum must be equal to the actual check sum.
1
2
DO: TM54F_MA, TM54F_SL
SI Extended Functions - Parameter manager
Changing Safety parameters
r10054.0
Safety parameterization enable
Password entry
=
x
y
<1>
SET
=
y = x
Effective password
<2>
<1>
Disabling Safety functions
SI drv_obj assign_MA
p10010[0...5] = 0
SI drv_obj assign_SL
p10010[0..5] = 0
3
4
SI act CRC TM54F_MA
r10004
Safety parameter
&
p10000 ... p10099
can be changed
r10004
SI act CRC TM54F_SL
Resetting safety parameters
Safety parameter
p10000 ... p10099
&
can be reset to
factory settings via
p0970
5
6
fp_2847_51_eng.vsd
15.11.11 V04.05.00
p10000 (12.00 ms)
SI ref CRC TM54F_MA
p10005
<3>
<1>
=
Safety parameters
p10000 ... p10099
&
are valid after
POWER ON
Checksum check
for
Safety parameters
=
<1>
<3>
p10005
SI ref CRC TM54F_SL
p0010
95
Quit Safety commissioning mode
7
Function diagram
SINAMICS
8
- 2847 -