Samsung SINAMICS G130 Mode D'emploi page 1057

Table des Matières

Publicité

24 V DC to the next device
X124.+
X124.+
X124.M
X124.M
X132.12
<1>
X132.13
<1>
X132.14
<1> The connection shown as a dashed line applies
when used as digital output (p0728.x = 1).
1
2
DO: CU_G, CU_GL, CU_GM, CU_MV, CU_S, CU_SL
CU320-2 input/output terminals - Digital inputs/outputs, bidirectional (DI/DO 14 ... DI/DO 15)
+24 V
M
M
p0728.14 (0)
DI
DI
0
DI/DO 14
24 V
<3>
1
DO
DO
p0728.15 (0)
DI
DI
0
DI/DO 15
5 V
<3>
1
DO
DO
M
<2> For SERVO and VECTOR (except for SINAMICS G130/G150), the following applies:
Can be used as fast measuring probe inputs (refer to [4735], [4740]).
<3> The digital output access authority is displayed in r0729.
3
4
p0796.14 (0)
p0795.14 (0)
DI 14_probe
1
r0721.14
<2>
0
p0748.14 (0)
0
1
1
1
r0747.14
0
0
p0796.15 (0)
p0795.15 (0)
DI 15_probe
1
r0721.15
<2>
0
p0748.15 (0)
0
1
1
1
r0747.15
0
0
5
6
fp_2133_51_eng.vsd
07.12.11 V04.05.00
p0799[0] (4000.00 μs)
DI/DO 14 ... 15
DI/DO 14 ... 15
inverted
r0723
r0722
1
r0723.14
r0722.14
CU S_src DI/DO 14
p0744
(0)
1
r0723.15
r0722.15
CU S_src DI/DO 15
p0745
(0)
7
8
Function diagram
- 2133 -
SINAMICS

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sinamics g150

Table des Matières