Télécharger Imprimer la page

Sunrise Medical Quickie IRIS Manuel D'instructions page 25

Masquer les pouces Voir aussi pour Quickie IRIS:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

IX. DEALER SERVICE AND ADJUSTMENT
O. CONTRACTURE FOOTREST
1.
Outside Mount - Can be mounted laterally
2.
Inside Mount - Can be mounted in the center
18
3.
Height Adjustment
a.
Loosen and remove the retaining bolt (A) in the footrest mounting bracket.
b.
Slide the lower tube upward or downward to the desired position until predrilled holes on
hanger tubes are aligned.
c.
Reinsert bolt (A) and tighten.
4.
Footrest Angle Adjustment
a.
Loosen the retaining bolt (B) in the adjustment locking joint.
b.
Position footrest foreword or rearward in desired angle.
c.
Retighten the bolt (B).
5.
Footplate Angle Adjustment
a.
Loosen the retaining bolt (C) in the footplate locking joint.
b.
Position footplate upward or downward in desired angle.
c.
Retighten the bolt (C).
P. Z-FINITY
FOOTREST SYSTEM
®
CAUTION– The Z-FINITY
®
footrest system is rated to 165lbs (75kg).
The footrest position is key to keeping the body in the proper alignment, and providing a stable support
for your legs and torso. Make sure that your Sunrise dealer has correctly adjusted your footrests and/or
legrests with the advice of a healthcare professional. The original setup should not be changed without first
checking with that advisor. Legrests and footrests should be swung out of the way, or removed for
transfers.
NOTE: Footplate must have at least 2 inches of clearance between the footplate and the ground to
prevent hitting obstacles and risking a fall or tip-over.
1.
Footrest/Footplate positioning using the rotational clamp
a.
Loosen the two rotational/angle clamp screws (D).
b.
Rotate the footrest/footplate until the desired position and angle is achieved.
c.
Tighten the clamp hardware to proper torque (DO NOT EXCEED a 120 in-lb Max torque).
2.
Footrest positioning using footplate spacers
a.
Remove footplate spacers (E).
b.
Slide footplate to desired depth position.
c.
Replace footplate spacers.
3.
Height range adjustment (Direct Mount Footrest)
a.
Adjust the footplate mounting position by removing the button head screw from the adjust-
ment hole and moving the assembly to the desired position.
b.
Tighten hardware to proper torque (120 in-lb Max).
4.
Height range adjustment (Extension Mount Footrest)
a.
Loosen set screw (F).
b.
Slide footrest extension tube up or down inside frame tube to desired height.
c.
Tighten set screw to proper torque (120 in-lb).