SYSTem
      :CHANnel
[:COUNt]?
            :MODel? (@chanlist)
            :OPTion? (@chanlist)
            :SERial? (@chanlist)
      :COMMunicate
            :LAN|TCPip:CONTrol?
            :RLSTate LOCal|REMote|RWLock
      :DATE <yyyy>,<mm>,<dd>
      :ERRor?
      :GROup
            :CATalog?
            :DEFine (@chanlist)
            :DELete (@channel)
                  :ALL
      :PASSword
            :FPANel
                  :RESet
      :PERSona
            :MANufacturer "<manufacturer>"
                  :DEFault
            :MODel "<model number>"
                  :DEFault
      :REBoot
      :SECurity
            :IMMediate
      :SET <data>
      :SET?
      :TIME <hh>,<mm>,<ss>
      :VERSion?
TRIGger
      :ACQuire
[:IMMediate] (@chanlist)
            :CURRent
[:LEVel] <value>, (@chanlist)
                  :SLOPe POSitive|NEGative, (@chanlist) Sets the current trigger slope.
            :SOURce <source>, (@chanlist)
            :TOUTput
[:ENABle] 0|OFF|1|ON, (@chanlist)
Keysight N6705C User's Guide
Returns the number of output channels in a mainframe.
Returns the model number of the selected channel.
Returns the option installed in the selected channel.
Returns the serial number of the selected channel.
Returns the initial socket control connection port number.
Configures the remote/local state of the instrument.
Sets the date of the system clock.
Reads and clears one error from the error queue.
(GROup commands do NOT apply to models N678xA SMU)
Returns the groups that have been defined.
Group multiple channels to create a single channel.
Remove the specified channel from the group.
Ungroups all channels.
Resets the front panel lockout password to zero.
Changes the manufacturer identity.
Sets the manufacturer identity to the factory default.
Changes the model number.
Sets the model number to the factory default.
Reboots the instrument to its power-on state.
Clears all user memory and reboots the instrument.
Sets the instrument to the specified state.
Retrieves the current instrument state.
Sets the time of the system clock.
Returns the SCPI version that the instrument complies with.
Triggers the measurement immediately.
Sets the current trigger level.
Selects the trigger source for the acquisition system:
BUS |CURRent<1-4> |EXTernal |PIN<1-7> |TRANsient<1-4> |VOLTage<1-4>
Enables measurement triggers to be sent to a digital port pin.