Télécharger Imprimer la page

Keysight N6705C Mode D'emploi page 22

Masquer les pouces Voir aussi pour N6705C:

Publicité

Les langues disponibles

Les langues disponibles

1 Quick Reference
Arbitrary Waveform Preview
Press Arb
This dialog displays the
arbitrary waveforms that have
been configured.
1. DC Value
2. Output
3. Wave shapes
4. Trigger Source
5. Repeat
6.
7. 3
8. Time
9. Close
22
This column indicates the present output voltage or current setting that appears at the output before the Arb is
run. The output will return to this value after the Arb complete if the Return to DC value box has been checked.
If the Last Arb Value box is checked, the output will remain at the last programmed Arb value.
This column identifies the output channel on which the associated waveform will run. Use the navigation keys
to select an output if you wish to select an Arb or edit the Arb on that output channel.
This column illustrates the waveshapes that will run on each output when the arb(s) are started. Note that all
Arbs will run simultaneously.
This dropdown list selects the trigger source for all configured Arbs.
This column indicates how many times the Arb will repeat if it has been configured to repeat. If the column is
blank, the Arb will only run once.
Indicates that the Arb on output 2 runs continuously.
Indicates that the Arb on output 3 repeats three times.
Indicates the time that the longest Arb will run. In this example, all Arbs run the same amount of time.
Closes the Arb Preview and returns to the previous measurement view.
Arb Preview
Keysight N6705C User's Guide

Publicité