1 Quick Reference
            :FUNCtion
                  :CURRent 0|OFF|1|ON, (@chanlist)
      :SWEep
            :OFFSet
                  :POINts <value>, (@chanlist)
            :POINts <value>, (@chanlist)
            :TINTerval <value>, (@chanlist)
                  :RESolution RES20|RES40
      :VOLTage
[:DC]
                  :RANGe
[:UPPer] <value>, (@chanlist)
                        :AUTO 0|OFF|1|ON, (@chanlist)
      :WINDow
[:TYPE] HANNing|RECTangular, (@chanlist)
[SOURce:]
      ARB
            :COUNt?
            :CURRent | :VOLTage | :POWer | :RESISTANCE
                  :CDWell
[:LEVel] <value>, {<value>}, (@chanlist)
                        :DWELl <value>, (@chanlist)
                        :POINts? (@chanlist)
                  :CONVert (@chanlist)
                  :EXPonential
                        :END
[:LEVel] <value>, (@chanlist)
                        :STARt
[:LEVel] <value>, (@chanlist)
                              :TIMe <value>, (@chanlist)
                        :TCONstant <value>, (@chanlist)
                        :TIMe <value>, (@chanlist)
                  :PULSe
                        :END
                              :TIMe <value>, (@chanlist)
                        :FREQuency <value>, (@chanlist)
                        :STARt
[:LEVel] <value>, (@chanlist)
                              :TIMe <value>, (@chanlist)
                        :TOP
[:LEVel] <value>, (@chanlist)
                              :TIMe <value>, (@chanlist)
32
Enables/disables current histogram.
Defines the offset in a data sweep for triggered measurements.
Defines the number of points in a measurement.
Defines the time period between measurement samples.
Sets the measurement resolution.
Selects a DC voltage measurement range.
Enables/disables seamless measurement autoranging. (N678xA SMU)
Selects the measurement window.
Sets the ARB repeat count.
Sets the Arb type (POWer and RESISTANCE only on N679xA)
Sets the list of the constant dwell Arb
Sets the dwell time for the constant dwell Arb
Returns the number of constant-dwell Arb points
Converts the selected Arb to a user-defined list
Sets the end level of the exponential Arb
Sets the initial level of the exponential Arb
Sets the length of the start time or delay
Sets the time constant of the exponential Arb
Sets the time of the exponential Arb
Sets the length of the end time
Sets the frequency of the pulse
Sets the initial level of the pulse
Sets the length of the start time or delay
Sets the top level of the pulse
Sets the length of the pulse
Keysight N6705C User's Guide