6 Advanced Source, Measurement, and Control
Autoranging
The following figure illustrates the autoranging output characteristic of the Keysight N675xA and
N676xA power modules
. Point 3 shows a situation in which the voltage and current
settings are such that the operating locus is limited by the maximum output power boundary of the
output. Depending on the power module, this may be greater than the output power rating of the
module. In this situation, the output is not guaranteed to meet its operating specifications because it is
operating in an area that is outside its specified power rating.
Keysight N6705C User's Guide
199