3 Using the Source/Load Functions
Parameter
Peak Width (T 2 )
Fall Time (T 3 )
End Time (T 4
Step 3. Configure the final steps common to all Arbs.
Refer to
Configuring Parameters Common to all Arbs
From the remote interface:
Select the Arb Type and Shape:
ARB:FUNC:TYPE VOLT,(@1)
ARB:FUNC:SHAP TRAP,(@1)
Enter the values for the level before and during the top of a voltage trapezoid:
ARB:VOLT:TRAP:STAR 0,(@1)
ARB:VOLT:TRAP:TOP 5,(@1)
Enter the time before the trapezoid, the rise-time,fall-time, top-time, and the time after the trapezoid:
ARB:VOLT:TRAP:STAR:TIM 0.25,(@1)
ARB:VOLT:TRAP:RTIM 0.5,(@1)
ARB:VOLT:TRAP:FTIM 0.5,(@1)
ARB:VOLT:TRAP:TOP:TIM 1.5,(@1)
ARB:VOLT:TRAP:END:TIM 0.25,(@1)
Configuring Exponential Arbs
Step 1. Select the Arb Type and Shape. Power and resistance types apply to
Press the Arb key twice or press the Arb key and then Properties to access the Arb Selection window.
In the Arb Type dropdown, select the Arb type. Then select Exponential.
Step 2. Configure the Exponential Properties:
Press the Properties key or select the Arb Properties button. Then program the following parameters:
112
Description
The width of the peak.
The time that the trapezoid ramps down.
The time the output remains at the end setting after the trapezoid completes.
at the end of this section.
Keysight N6705C User's Guide
: