Télécharger Imprimer la page

Keysight N6705C Mode D'emploi page 110

Masquer les pouces Voir aussi pour N6705C:

Publicité

Les langues disponibles

Les langues disponibles

3 Using the Source/Load Functions
Step 2. Configure the Pulse Properties:
Press the Properties key or select the Arb Properties button. Then program the following parameters:
The I
and I
parameters shown apply
0
1
to the Current Arb type.
The V
, V
, P
, P
, R
, and R
0
1
0
1
0
parameters apply to the respective
Voltage, Power and Resistance Arb
types.
Parameter
Start Setting (I 0 , V 0 , P 0 , or R 0 )
Pulse Setting (I 1 , V 1 , P 1 , or R 1 )
Delay (T 0 )
Pulse Width (T 1 )
End Time (T 2 )
Frequency
Step 3. Configure the final steps common to all Arbs.
Refer to
Configuring Parameters Common to all Arbs
From the remote interface:
Select the Arb Type and Shape:
ARB:FUNC:TYPE VOLT,(@1)
ARB:FUNC:SHAP PULS,(@1)
Enter the values for the level before and the top of a voltage pulse:
ARB:VOLT:PULS:STAR 0,(@1)
ARB:VOLT:PULS:TOP 10,(@1)
110
1
Description
The setting before and after the pulse.
The amplitude of the pulse.
The delay after the trigger is received but before the pulse starts.
The width of the pulse.
The time the output remains at the end setting after the pulse completes.
Enter a frequency value directly. this will change the (T 0 ), (T 1 ), (T 2 ) parameters
at the end of this section.
Keysight N6705C User's Guide

Publicité

loading