6.
Setting up
6.1.
Operating location
⇒ The kiln is not intended for outdoor installation or outside of closed rooms.
⇒ Minimum requirements for the operating location of the kiln:
Sufficient distance of at least 50 cm from walls, other plant and machinery and traffic routes
-
Traffic routes for kiln maintenance should be generously dimensioned at more than 50 cm.
-
Floor, ceiling insulation, walls, partitions, cladding etc., must be made of flame-retardant material.
-
Sufficient distance from flammable objects
-
Sufficient distance from sprinkler systems
-
Sufficient distance from machines or systems with strong electromagnetic radiation (impairment of the
-
control system)
The switchgear and maintenance areas on the kiln must be freely accessible.
-
⇒ The kiln:
may only be set up in a well-ventilated room.
-
must not be operated in rooms with flammable material.
-
must be set up on a non-flammable surface.
-
must not be installed in garages, summer houses, covered terraces, balconies or boiler rooms.
-
⇒ The kiln may only be used in closed rooms without:
potentially explosive areas
-
fire hazard areas
-
the possibility of condensation.
-
⇒ The following requirements for the installation area must be observed:
The installation area must be able to take the load.
-
The surface must be even (+/- 3 mm).
-
The surface must be vibration-free and suitable for the static and dynamic loads of the kiln.
-
⇒ Avoid environmental influences such as loud noise, water or moisture, heavy contamination (especially
dust), acids, alkalis, etc.
⇒ Adequate lighting of the operating location and the work area must be ensured.
6.2.
General installation & assembly
6.2.1.
General safety information
DANGER
Risk of serious personal injury and property damage caused by:
WARNING
Risk of serious personal injury and property damage:
Only have work such as installation carried out by specially trained and authorised
personnel.
⇒ loss of stability or placing the kiln on surfaces that are not sufficiently stable or
⇒ a poorly prepared operating location.
86 / 298 - EN -