3.8.
Additional safety information
3.8.1.
Monitored operation
The kiln should be used in monitored operation. In the case of monitored operation, the operating status of the kiln
must be checked at sufficiently short time intervals.
3.8.2.
Work on electrical components
Work on electrical components may only be carried out by a trained and qualified electrician, taking into account the
five safety rules of electrical engineering.
3.8.3.
Residual risks
During the design and construction of the kiln, special attention was paid to safety, and special safety precautions
and additional protective measures for the operation of the kiln were developed.
Nevertheless, residual risks remain. The respective valid standards and corresponding occupational health and
safety regulations always have priority.
4.
Use
4.1.
General safety information
DANGER
Risk of serious personal injury, property damage and even death due to improper use
of the kiln.
Use the kiln only as intended and in technically perfect condition! Any use beyond this is
considered improper and is not permitted. The manufacturer is not liable for any resulting
damage.
4.2.
Field of applications of the kiln
General use
Industry
Crafts
Domestic
Special area of application
Food industry (contact with food)
Pharmaceutical industry
Cosmetic industry
Fusing
No
Yes
Yes
Fusing
No
No
No
73 / 298 - EN -
FE series
Yes
Yes
No
FE series
No
No
No