Connecting The Bus Coupler's Logic And Load Supply - Aventics CANopen Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 163
PO WE R
X10
2
1
3
4
AVENTICS | CANopen | R412005742–BDL–001–AD
6.3.4
Connecting the bus coupler's logic and load
supply
Power is supplied to the valves and the bus coupler via the X10
plug (POWER).
When connecting the logic and load supply of the bus coupler,
ensure pin assignment according to Tab. 6.
Table 6:
Assignment of the X10 (POWER) plug, M12, A-coded
Pin
X10
Assignment
1
U
Voltage supply for bus coupler logic and sensor
L
supply for digital input modules
2
U
First valve voltage supply
Q1
3
OV
Ground for U
4
U
Second valve voltage supply
Q2
U
, U
and U
are galvanically connected to one another.
W
L
Q1
Q2
With the U
and U
W
Q1
switched off byte by byte (each byte represents 4 bistable or
8 mono-stable valves).
The S4, S5, and S6 sliding switches are used to assign the
W
valve groups (4 or 8 valves) (see "Assigning the valve
supply" on page 116). It is therefore possible to shut down
before or after an emergency OFF.
The voltage supply cable must fulfill the following
requirements:
Cable socket: 4-pin, A-coded without center hole
W
Cable cross-section: per wire > 0.5 mm
W
Length: Max. 20 m
W
U
and U
Q1
Q2
,
L
valve supplies, the valves can be
Q2
2
107
Assembly

Publicité

Table des Matières
loading

Table des Matières