112
AVENTICS | CANopen | R412005742–BDL–001–AD
Assembly
VS HF04 grounding
VS HF03 LG grounding
6.3.7
FE connection
To discharge EMC interferences, connect the
O
FE connection (1) on the EP end plate of the VS via a low-
impedance line with a functional grounding.
Recommended cable cross-section: 10 mm
When delivered, the screw for the FE connection is assembled
on the EP end plate of the VS. As an alternative, the FE
connection can be made on the E end plate (2) (see also Fig. 1 on
page 97).
To do this, unscrew the screw for the FE connection from the
O
EP end plate of the VS (1) and screw it into the E end plate
(2). Then establish the connection with functional grounding
there.
Fig. 7:
FE connection on the VS HF04 with CANopen on the EP end
plate (1) or an E end plate (2)
Affix the grounding on the FE connection of the E end plate
O
(2).
2
2
1