Connecting The Bus Coupler; Connecting The Bus Coupler Logic And Load Supply - Aventics EtherNet/IP Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 79
2
1
3
4
5
BUS X72
1
2
4
3
2
1
POW ER
X10
2
1
3
4
AVENTICS | EtherNet/IP™ | R412012728–BDL–001–AC
Table 5:
X71 pin assignment (RS232), M12, 5-pin
Pin
Signal
1
nc
2
nc
3
RXD
4
GND
5
TXD
Table 6:
X72 (BUS) assignment, M12, D-coded
Pin
Signal
1
TD+
2
RD+
3
TD-
4
RD-
1
TD+
The connection technology and plug assignment comply with the specifications
in the technical guidelines Network Infrastructure for EtherNet/IP™ Publication
Number: PUB00035R0.
6.3.2

Connecting the bus coupler

1. Set up the correct pin assignment (see tab. 6 on page 53) on the plug connections
if you do not use pre-assembled cables.
2. Connect the incoming bus connection to X72 (1) and connect the module with
a hub or switch if further participants are to be connected.
3. Provide the X71 plug (2) with a cover cap.
4. Connect the shield on both sides of the bus cable directly to the plug housing
(EMC housing) if self-assembled cables and plugs with metal housing are used.
This protects data lines from terminal interference. Ensure that the plug housing
is securely fitted to the bus coupler housing.
6.3.3

Connecting the bus coupler logic and load supply

Power is supplied to the valves and the bus coupler via the X10 (POWER) plug.
When connecting the logic and load supply of the bus coupler, ensure pin assignment
according to tab. 7.
Table 7:
Assignment of the X10 (POWER) plug, M12, A-coded
Pin
X10
Assignment
1
U
Power supply for bus coupler logic and sensor supply
L
for digital input modules
2
U
First valve power supply
Q1
3
OV
Ground for U
4
U
Second valve power supply
Q2
Meaning
Not Connected
Not Connected
Received data
Reference potential to 0 V
Transmission data
Meaning
Transmit pos.
Receive pos.
Transmit neg.
Receive neg.
Transmit pos.
U
and U
L,
Q1
Q2
53