4. PRESENTATION.
4.1.
VIEWS.
4.1.1.
Views of the equipment.
Figures from 1 to 20 show the illustrations of the equipments ac-
cording to model, nominal operating voltage and input-output setting,
which is summarised in the chart 1.
Format of protections and size of the terminals shown in the figures
of this document, always correspond to the highest power rate model
manufactured in that cabinet, at the same power supply voltage and
input-output setting.
Nevertheless and as the product is in constant evolution, some dis-
crepancies or small contradictions can arise. So, if any questions, the
labels over the own equipment will prevail.
Each equipment model corresponds to one power rate,
voltage, frequency and input and output currents. All values
of these features can be checked in the nameplate, located
at the back of the front door (PF), and act in your installation
accordingly.
Input - output
Model
setting
SLC-5-CUBE3+
SLC-7,5-
No ref. : III / III
CUBE3+
L : I / I
SLC-10-CUBE3+
M : I / III
SLC-15-CUBE3+
N : III / I
SLC-20-CUBE3+
SLC-30-CUBE3+
SLC-40-CUBE3+
SLC-50-CUBE3+
Available at
SLC-60-CUBE3+
setting III / III
SLC-80-CUBE3+
only
SLC-100-
CUBE3+
The equipments with separate static Bypass line (-B), are supplied in the same cabinet as basic models, less those ones stated in this
(0)
chart with other Nr of Fig.
Table 1. Reference relation among models and illustration.
SALICRU
Power (kVA / kW)
Voltage (V)
Setting
III/III
L / M / N
5 / 4.5
7.5 / 6.75
10 / 9
15 / 13.5
«LV»
20 / 18
3x200.. 3x230 V
30 / 27
(115.. 133 V in
40 / 36
single phase)
50 / 45
60 / 54
80 / 72
100 / 90
In the description of this manual, there are references to «LV» (Low
voltage) and «HV» (High voltage) abbreviations, described in the no-
menclature of the model with an «A» for «LV» and omitted for «HV»,
grouping the following interval of voltages:
• LV.- 3x200 to 3x230 V (115 to 133 V in single phase).
• HV.- 3x380 to 3x415 V (220 to 240 V in single phase).
These abbreviations do not have any other purpose than matching
and/or helping in order to give a better comprehension of the de-
tailed information in this document and even they are not shown
either in the nomenclature, or in the reference of the nameplate
model.
All models can operate as single units or connected in parallel with
other equipments of the same family, because the needed elec-
tronic kit is already included.
Parallel connection can be done at any time when the upgrading
requirements are needed to increase the supplied power of the
equipment or in order to have redundant operating systems for in-
stallations with higher safety.
Do not connect SLC CUBE3+ equipments of different features
versions, settings, back up times or duplicated addresses (i.e.: two
equipments, although they are identical, coming from two parallel
systems and with the same address) in parallel.
In any parallel system only one and different address is assigned to
each equipment that makes the system.
Fig. nr. Front UPS cabinet
Setting
Door closed
Door opened
5 / 4
7.5 / 6
10 / 8
1
6 / 7 / 8 / 9
15 / 12
20 / 16
30 / 24
40 / 32
2
50 / 40
2
3 for (-B)
12 for (-B)
60 / 48
(0)
(0)
80 / 64
4
5 for (-B)
14 for (-B)
(0)
(0)
100 / 80
Fig. nr. Front battery cabinet
Door closed
Door opened
Battery cabinet
Battery cabinet
for extended
for extended
back up time
back up time
models only,
models only,
ver 15
ver 16
15
10
17
11
13
19
16
18
20
81