Nominal power (kVA)
Nominal power (kW)
Total output voltage harmonic distortion
Phase shifting
Dynamic response time
Permissible overload
(7)
Permissible crest factor
Permissible power factor
Unbalanced output voltage (100 % unbalanced load)
Current limit
Efficiency on battery mode (100% linear load) (%)
STATIC BYPASS
Type
Bypass line
Nominal voltage
Voltage range
Voltage hysteresis
Frequency
Frequency range
Frequency hysteresis
Activation criteria
Transference time
Permissible overload
Transference to bypass
Re-transference
Efficiency on Smart ECO Mode (%)
MANUAL BYPASS (MAINTENANCE)
Type
Nominal voltage
Frequency
SHORT CIRCUIT CURRENT (kA)
GENERAL
Total efficiency (100% linear load) (%)
BATTERIES
Quantity
(8)
Type
Floating voltage per battery
Compensation of the battery floating voltage
Capacity (Ah)
Standard charging current (Cx0,2) (A)
Battery terminal torque
Fitted in the same UPS cabinet
DIMENSIONS AND WEIGHTS FOR UPS CONFIGURATIONS WITH STANDARD BACK UP TIME
Quantity of cabinets
Maximum
CUBE3+ / CUBE3+ B1
dimensions(mm)
CUBE3+ B / CUBE3+ B B1
(Depth x Width x
Batteries
Height)
Casters without brake. Equipment / batteries
CUBE3+ B1
CUBE3+ B B1
Cabinet weight (kg)
CUBE3+
CUBE3+ B
External batteries
Table 9. Technical specifications of equipments with (HV) voltage.
Additional informations referred to charts 8 and 9:
– UPSs up to 20 kVA (LV) / 40 kVA (HV) with standard
back up time are supplied in only one cabinet, batteries
included. For extended back up times and/or higher
power rates, the UPS and batteries are supplied in
separate cabinets.
144
7.5
10
15
20
30
Depending on the input/output setting and power supply voltage (See chart 9)
Linear load: THD-v < 0.5 %. Ref. non-linear load (EN-62040-3): THD-v < 1.5 %
120 ±1º (balanced load). 120 ±2º (unbalanced load of 100 % )
125 % for 10 min., >125.. 135 % for 5 min., >135.. 150 % for 1 min., > 150 % for 20 ms.
3.4 to 1
High overload, short-circuit: RMS voltage limit. High current crest factor: Peak voltage limit
94.3
94.8
95.3
95.6
95.9
Common. Separate as an option (B)
Single phase 220V, 230V or 240V
Three phase 3x380V, 3x400V or 3x415V (4 wires: 3 phases + N)
Preset +12 % (adjustable between +20... +5%) / –15% (adjustable between –25... –5%
±2 % as regards to bypass voltage range. In a standard equipment is of +10 /–13%
±5 Hz (selectable among 0.5 - 1.0 - 2 and 5.0 Hz)
1 Hz as regards the frequency range (selectable among 0.2 - 0.5 - 1.0 and 2.0 Hz)
Nil, less in Smart ECO Mode < 4 ms
Immediate, for overloads higher than 150 %
95
95.5
96
97.4
Single phase 220V, 230V or 240V
Three phase 3x380V, 3x400V or 3x415V (4 wires: 3 phases + N)
6
91.0
92
92.5
93.5
4.5
7
9
0.9
1.4
1.8
YES
1 (UPS + batteries)
775x450x1100
-
YES / -
97
97
99
102
147
99
99
101
105
150
207
207
209
235
319
209
209
211
237
322
-
-
-
-
-
40
50
60
80
10 ms. at 98 % of the static value
3.2 to 1
2.8 to 1
0.7 leading to 0.7 lagging
< 1 %
96.4
96.3
96.4
96.4
Solid state
50 / 60 Hz
Controlled by microprocessor
400 % for 10 s
Automatic after alarm cancelling
97.8
98
98.4
Make before break
50 / 60 Hz
10
25
94.0
95.0
31 + 31
Pb-Ca
13.65 V at 20ºC
Adjustable (Preset to –18 mV/ºC)
12
12
2x12
2.4
2.4
4.8
According to battery manufacturer
1 (UPS) / 1 (batteries)
880x590x1325
1050x650x1325
YES / YES
172
-
-
-
175
-
-
-
417
185
185
265
420
190
190
275
-
321
551
1020
100
120
160
200
3.2 to 1
3 to 1
96.5
96.4
96.8
96.9
-
98
-
100
94.5
94.0
95.0
40
65
80
8.0
13
16
NO
850x900x1905
880x870x1325 850x1225x1905
850x1305x1905
YES / NO
NO / NO
-
-
-
-
-
-
-
-
290
290
540
550
310
310
570
580
1020
1020
1655
1690
USER MANUAL