2 Installation
Step 2. Install the power module.
Align the module over the pins and push it down onto the mainframe connector. Install a filler module
in any unused slots.
Step 3. Install the screws at each end of the module.
Use a T10 Torx driver to tighten the screws. Because the RFI strips apply upward pressure, continue
pushing down on the module until the screws are tight.
Step 4. Replace the blower cover when finished.
Carefully fit the spring clips under the lip of the modules.
Power Module Channel Assignment
The slot location of a module in the mainframe determines the channel assignment of the module.
When viewed from the rear, the module next to the GPIB connector is always output channel one.
Numbering continues sequentially to the left, from 1 up to 4.
Double-wide modules are assigned the number of the lowest numbered slot in which is installed. For
example, if a double-wide module is installed in slots 3 and 4, it is assigned channel number 3.
Keysight N6700C Series User's Guide
51