Télécharger Imprimer la page

Keysight Technologies N6700C Serie Guide D'utilisation page 119

Publicité

Les langues disponibles

Les langues disponibles

4 Operating the Power System
For the user-defined waveforms, you can specify up to 511 step-points for each waveform. You can
specify a different dwell time for each of the step-points. The output will step through the user-defined
values, staying at each point for the programmed dwell time, and then moving on to the next point.
You can combine a number of individual arbitrary waveforms into an Arb sequence, as long as the total
number of points of all waveforms does not exceed 511 points.
Configuring Step Arbs
Step 1. Select the Arb Type and Shape. Power and Resistance types apply to
Front Panel Menu Reference
Select Transient\Arb\Function.
Select a Voltage, Current, Power, or Resistance Arb Type.
Then select the Step Shape. Then press Select.
Step 2. Configure the step parameters. The parameters apply to the selected Arb type (Voltage,
Current, Power, or Resistance).
Enter the values for the level before and after the step.
Enter the time before the step.
Front Panel Menu Reference
Select Transient\Arb\Config\Step\Level.
Enter the Start and End level in volts. Then press Select.
Select Transient\Arb\Config\Step\Time.
Enter the Start and End time in seconds. Then press Select.
Step 3. Configure the final steps common to all Arbs. Refer to
the end of this section.
Configuring Pulse Arbs
Step 1. Select the Arb Type and Shape. Power and Resistance types apply to
118
SCPI Command
To select a current, voltage, power, or resistance step Arb,
use:
ARB:FUNC:TYPE CURR|VOLT|POW|RES,(@1)
ARB:FUNC:SHAP STEP,(@1)
SCPI Command
To configure a voltage step Arb, use:
ARB:VOLT:STEP:STAR 0, (@1)
ARB:VOLT:STEP:END 10, (@1)
ARB:VOLT:STEP:STAR:TIM 0.25,(@1)