1 Quick Reference
                        :AUTO 0|OFF|1|ON, (@chanlist)
      :WINDow
[:TYPE] HANNing|RECTangular, (@chanlist)
[SOURce:]
      ARB
            :COUNt?
            :CURRent | :VOLTage | :POWer | :RESISTANCE
                  :CDWell
[:LEVel] <value>, {<value>}, (@chanlist)
                        :DWELl <value>, (@chanlist)
                        :POINts? (@chanlist)
                  :CONVert (@chanlist)
                  :EXPonential
                        :END
[:LEVel] <value>, (@chanlist)
                        :STARt
[:LEVel] <value>, (@chanlist)
                              :TIMe <value>, (@chanlist)
                        :TCONstant <value>, (@chanlist)
                        :TIMe <value>, (@chanlist)
                  :PULSe
                        :END
                              :TIMe <value>, (@chanlist)
                        :STARt
[:LEVel] <value>, (@chanlist)
                              :TIMe <value>, (@chanlist)
                        :TOP
[:LEVel] <value>, (@chanlist)
                              :TIMe <value>, (@chanlist)
                  :RAMP
                        :END
[:LEVel] <value>, (@chanlist)
                              :TIMe <value>, (@chanlist)
                        :RTIMe <value>, (@chanlist)
                        :STARt
[:LEVel] <value>, (@chanlist)
                              :TIMe <value>, (@chanlist)
                  :SINusoid
                        :AMPLitude <value>, (@chanlist)
                        :FREQuency <value>, (@chanlist)
                        :OFFSet <value>, (@chanlist)
                  :STAIRcase
30
Enables/disables seamless measurement autoranging. (N678xA SMU)
(WINDow command only on N676xA, N678xA SMU, Option 054)
Selects the measurement window.
(ARB commands only on N676xA, N678xA SMU, Option 054)
Sets the ARB repeat count.
Sets the Arb type (POWer and RESISTANCE only on N679xA)
Sets the list of the constant dwell Arb
Sets the dwell time for the constant dwell Arb
Returns the number of constant-dwell Arb points
Converts the selected Arb to a user-defined list
Sets the end level of the exponential Arb
Sets the initial level of the exponential Arb
Sets the length of the start time or delay
Sets the time constant of the exponential Arb
Sets the time of the exponential Arb
Sets the length of the end time
Sets the initial level of the pulse
Sets the length of the start time or delay
Sets the top level of the pulse
Sets the length of the pulse
Sets the end level of the ramp
Sets the length of the end time
Sets the rise time of the ramp
Sets the initial level of the ramp
Sets the length of the start time or delay
Sets the amplitude of the sine wave
Sets the frequency of the sine wave
Sets the DC offset of the sine wave