Running the Arb
Step 6. Enable the Arb function to respond to output triggers.
Front Panel Menu Reference
Select Transient\Mode.
For voltage, current, power, or resistance Arb triggering,
set the mode to Arb. Then press Select.
Step 7. Select the Arb trigger source.
Select a trigger source from the following:
Bus Selects GPIB device trigger, *TRG, or <GET> (Group Execute Trigger).
l
Imm An immediate trigger command either from the front panel or over the bus will generate an
l
immediate trigger.
Ext Selects all digital port pins that have been configured as trigger inputs.
l
Pin<n>Selects a specific pin that is configured as a Trigger Input on the digital port.<n> specifies
l
the pin number. The selected pin must be configured as a Trigger Input in order to be used as a trig-
ger source (refer to
Trigger
Use the following commands to select a trigger source:
Front Panel Menu Reference
Select Transient\TrigSource.
Under Arb trigger source, select Bus.
To select Digital pin triggers, select Transient\TrigSource.
Then select one of the digital port pins. (Ext selects all pins
that have been configured as trigger inputs.)
Then press Select.
Step 8. Initiate and Trigger the Arb.
Front Panel Menu Reference
Select Transient\Control.
Select Initiate.
Wait a second, then select Trigger to generate an
immediate trigger signal regardless of the trigger source
setting.
Keysight N6700C Series User's Guide
To enable the Arb to respond to triggers, use:
VOLT:MODE ARB,(@1)
CURR:MODE ARB,(@1)
POW:MODE ARB,(@1)
RES:MODE ARB,(@1)
Input).
To select Bus triggers for Arbs, use:
TRIG:ARB:SOUR BUS,(@1)
To select Immediate triggers for output 1: TRIG:ARB:SOUR
IMM,(@1)
To select Digital pin triggers: TRIG:ARB:SOUR PIN<n>,(@1)
where n is the pin number.
To initiate the transient trigger system and generate a trigger:
INIT:TRAN (@1)
TRIG:TRAN (@1)
Alternatively, you can also program a *TRG or an IEEE-488
<get> command.