4 Operating the Power System
Front Panel Menu Reference
Select Transient\Arb\Config\CD.
Enter a Dwell time in seconds. Select a point number and
enter a value for that point. Then press Select.
Step 3. Configure the final steps common to all Arbs. Refer to
the end of this section.
Configuring an Arb Sequence
Arb Sequences can only be programmed using SCPI commands. However, individual
Arbs within the sequence can be programed from the front panel and with SCPI
commands as previously discussed.
The Arb Sequence allows multiple and different Arbs to run one after another is succession. Any of the
standard Arb types, except for constant-dwell Arbs, can be included in the Arb sequence. All Arbs in
the sequence must be of the same type; either voltage, current, resistance, or power.
As with single Arbs, each Arb in the sequence has its own repeat count, can be set for dwell or trigger
pacing, and can be set to repeat continuously. Note also that a repeat count can be set for the entire
sequence, and it can also be set to repeat continuously.
Sequence steps must be specified sequentially. The last value in the parameter list is the sequence
step number. When a step is added, all Arb parameters must be entered.
The following figure illustrates a sequence comprised of a pulse Arb, a ramp Arb, and a sine Arb. The
repeat count value indicates how many times each Arb repeats before moving to the next type.
124
SCPI Command
To configure a voltage CD Arb of 10 points, use:
ARB:VOLT:CDW:DWEL 0.01,(@1)
ARB:VOLT:CDW 1,2,3,4,5,6,7,8,9,10,(@1)
Configuring Steps Common to all Arbs
Keysight N6700C Series User's Guide