4 Operating the Power System
Step 3. Configure the final steps common to all Arbs. Refer to
the end of this section.
Configuring Exponential Arbs
Step 1. Select the Arb Type and Shape. Power and Resistance types apply to
Front Panel Menu Reference
Select Transient\Arb\Function.
Select a Voltage, Current, Power, or Resistance Arb Type.
Then select the Exponential Shape. Then press Select.
Step 2. Configure the exponential parameters. The parameters apply to the selected Arb type
(Voltage, Current, Power, or Resistance).
Enter the values for the level before and after the exponential.
Enter the time before the exponential, the exponential time, and the time constant of the exponential.
Front Panel Menu Reference
Select Transient\Arb\Config\Exp\Level.
Enter the Start and End level in volts. Then press Select.
Select Transient\Arb\Config\Exp\Time.
Enter the Start, Time, and Time Constant (TC) in seconds.
Then press Select.
Step 3. Configure the final steps common to all Arbs. Refer to
the end of this section.
Configuring Sinusoid Arbs
Step 1. Select the Arb Type and Shape. Power and Resistance types apply to
Front Panel Menu Reference
Select Transient\Arb\Function.
Select a Voltage, Current, Power, or Resistance Arb Type.
Then select the Sine Shape. Then press Select.
122
Configuring Steps Common to all Arbs
SCPI Command
To select a current, voltage, power, or resistance exponential
Arb, use:
ARB:FUNC:TYPE VOLT|CURR|POW|RES,(@1)
ARB:FUNC:SHAP EXP,(@1)
SCPI Command
To configure a voltage step Arb, use:
ARB:VOLT:EXP:STAR 0, (@1)
ARB:VOLT:EXP:END 10, (@1)
ARB:VOLT:EXP:STAR:TIM 0.25,(@1)
ARB:VOLT:EXP:TIM 0.5,(@1)
ARB:VOLT:EXP:TCON 0.25,(@1)
Configuring Steps Common to all Arbs
SCPI Command
To select a current, voltage, power, or resistance sinusoid Arb,
use:
ARB:FUNC:TYPE VOLT|CURR|POW|RES,(@1)
ARB:FUNC:SHAP SIN,(@1)