Keysight Technologies N6700C Serie Guide D'utilisation page 30

Publicité

Les langues disponibles

Les langues disponibles

      :RELay
            :POLarity NORMal|REVerse, (@chanlist)
      :SHORt
[:STATe] 0|OFF|1|ON
SENSe
      :CURRent
            :CCOMpensate 0|OFF|1|ON, (@chanlist)
[:DC]
                  :RANGe
[:UPPer] <value>, (@chanlist)
                        :AUTO 0|OFF|1|ON, (@chanlist)
      :ELOG
            :CURRent
[:DC]
                        :RANge
[:UPPer] <value>, (@chanlist)
                              :AUTO 0|OFF|1|ON, (@chanlist)
            :FUNCtion
                  :CURRent 0|OFF|1|ON, (@chanlist)
                        :MINMax 0|OFF|1|ON, (@chanlist)
                  :VOLTage 0|OFF|1|ON, (@chanlist)
                        :MINMax 0|OFF|1|ON, (@chanlist)
            :PERiod <value>, (@chanlist)
            :VOLTage
[:DC]
                        :RANge
[:UPPer] <value>, (@chanlist)
                              :AUTO 0|OFF|1|ON, (@chanlist)
      :FUNCtion <"function">, (@chanlist)
            :CURRent 0|OFF|1|ON, (@chanlist)
            :VOLTage 0|OFF|1|ON, (@chanlist)
                  :INPut MAIN|AUXiliary, (@chanlist)
      :SWEep
            :OFFSet
                  :POINts <value>, (@chanlist)
            :POINts <value>, (@chanlist)
            :TINTerval <value>, (@chanlist)
                  :RESolution RES20|RES40
      :VOLTage
[:DC]
                  :RANGe
[:UPPer] <value>, (@chanlist)
Keysight N6700C Series User's Guide
Sets the polarity of the output relays. (Option 760)
Simulates a short circuit on the input of the load. (N679xA )
Enables/disables the capacitive current compensation. (not on
N678xA SMU, N679xA)
Selects a DC current measurement range.
Enables/disables seamless measurement autoranging. (N678xA SMU)
(ELOG commands only on N676xA, N678xA SMU, Option 054)
Selects the Elog current measurement range.
Enables/disables seamless measurement autoranging. (N678xA SMU)
Enables/disables current data logging.
Enables/disables min/max current data logging.
Enables/disables voltage data logging.
Enables/disables min/max voltage data logging.
Sets the integration time of an Elog measurement.
Selects the Elog voltage measurement range.
Enables/disables seamless measurement autoranging. (N678xA SMU)
Selects the measurement function (for backward compatibility)
Enables/disables current measurements (replaces FUNCtion)
Enables/disables voltage measurements (replaces FUNCtion)
Selects the voltage measurement input. (N6781A, N6785A)
(SWEep commands only on N676xA, N678xA SMU, Option 054)
Defines the offset in a data sweep for triggered measurements.
Defines the number of points in a measurement.
Defines the time period between measurement samples.
Sets the measurement resolution.
Selects a DC voltage measurement range.
1 Quick Reference
29