30
AVENTICS | CANopen | R402001988–BDL–001–AC
Electrical connections
1
4
2
3
Fig. 3:
Assignment round
plug-in connector
(X1S)
1
2
5
3
4
Fig. 4:
Assignment data
plug (X7C)
Fig. 2:
Plug position
5.1
Power supply connection
1 Pin 1: 24 V electronics
2 Pin 2: 24 V valve
5.2
Data line connection
1 Pin 1: Shield
2 Pin 2: not used
3 Pin 3: 0 V Bus
5.3
Data line selection
The type of data line is determined by the bus length, the
transfer rate and the demands of the bus manufacturer. Exact
specifications can to be found in the documentation: CiA DS-102,
CAN Physical Layer for Industrial Applications, April 1994.
3 Pin 3: 0 V
4 Pin 4: FE
4 Pin 4: CAN-H
5 Pin 5: CAN-L