5. TROUBLESHOOTING
The information below and the booklet "spare parts" do not authorise the user
to operate on the machine in case of malfunction. They provide the technical
support centre with accurate information so as to reduce intervention times. Any
intervention on the machine or on the system must be performed by qualified and
authorised personnel.
Lack of power supply
The motor is not running
Gear unit clamped
Control faulty
Gear unit clamped
Gear unit noisy. The backing pad makes 1/3 of a revolution and then stops
Gear unit seizing
Turntable stops under strain, but the motor is running
Insufficient belt tension
Pedal return spring broken
Manuale d'uso S 200
CAUTION
Backing pad does not turn
- Check that mains voltage is present.
- Check the state of fuses.
- Check the state of the differential and/or magneto-thermal
circuit-breaker.
- Check cable connections in the plug.
- Check the micro-switches of the pedal unit (only for motor
inverter)
- Check the rotation control of the pedal unit motor
- Replace the inverter board (only for motor inverter).
- Replace the motor.
Replace gear unit
Turntable does not rotate in either direction
-Replace the inverter.
- Check the micro-switches of the pedal unit (only for motor inverter)
- Replace the inverter board (only for motor inverter).
Replace gear unit.
Replace gear unit.
Adjust tension or replace belt.
Control pedals do not return to their position
Replace the spring.
155