INSTALLATION
!
Check for leaks by spraying all connection points with
a soap solution made of dishwashing soap and water. If
you see soap bubbles, this would be an indication of a
leak and it should be corrected. Check each connection
point, there should not be a visible bubbling with the
soap solution applied. Refer to the "Fuel Pipe Sizing
Chart" contained in this manual or the Installation
Manual for your specific HSB model. Installed
piping must be properly purged and leak tested, in
accordance with applicable codes and standards.
Champion HSB units have been run and tested at the factory
prior to shipment. They do not require any type of break-in
period.
FUEL PIPE SIZING CHART
Reduced pipe size will affect fuel delivery and performance.
Measure the pipe length from the generator fuel inlet to the
primary gas pressure regulator.
Pipe Length*
25 ft (8 m)
50 ft (15 m)
100 ft (30 m)
150 ft (46 m)
200 ft (61 m)
*Add 2.5 ft (0.76 m) per bend, tee or angle in the pipe line to
overall distance, for each 90 degree elbow, add 8 feet (2.4 m) to
the overall measurement.
28
Part No. 101049 Rev. B
CAUTION
NOTICE
LPG
3/4 in. NPT
3/4 in. NPT
1 in. NPT
1 in. NPT
1 in. NPT
5. CONVERTING TO LPG
The engine is fitted with a dual Master Mixer Assembly
(carburetor system), which allows the HSB to run on either NG or
LPG. It has been configured at the factory to run on NG. If your
installation requires to run on LPG, an orifice in the Master Mixer
Assembly (carburetor system) must be changed. The LPG orifices
are shipped with the HSB.
1.
Loosen the clamp, disconnect the fuel delivery hose from
the bottom of the mixing valve.
2.
Use a flat-head screwdriver to remove the idle/low speed
orifice (jet) counter clockwise and main orifice (jet) from
the mixing valve counter clockwise.
3.
Install the LPG orifices (jets) in the mixing valve clockwise.
Tighten the low speed orifice (jet) to 15.9 – 22.1 lb.-in.
(1.8 – 2.5 N m). The main orifice (jet) to 10.6 – 13.2 lb.-
in. (1.2 – 1.5 Nm).
4.
Re-install the fuel delivery hose and tighten the clap
securely. Check the connection for fuel leaks after
installing fuel supply.
5.
LPG jet markings on face of jet; LPG main jet L41, LPG
idle jet L0