Changing the Hardware Panel Network Settings
Because ATEM 1 M/E Advanced Panel is also on the network and communicating with the
switcher, it also has network settings so it can connect to the network. These settings are
different to the switcher IP address, which is just where the panel is looking to find the switcher.
The panel network settings can be changed by following the steps below:
Changing Network Settings on ATEM 1 M/E Advanced Panel
Change network settings using the system
control buttons and LCD soft controls
1
Press the 'home' button in the system control buttons to open the LCD home menu.
2
In the home menu, press the 'network' soft button to open the network settings.
3
The next step is to decide if you want the panel to use a fixed IP address or to be
automatically assigned an IP address from a DHCP server. Set DHCP on or off by
pressing the corresponding DHCP ON/OFF soft button.
NOTE
If you're connecting direct to a switcher without a network, then you
won't have a DHCP server to assign an IP address automatically, so you will
want to select 'DHCP off'. ATEM 1 M/E Advanced Panel is delivered with a
fixed IP address set to 192.168.10.60 for a direct connection.
However, if your network has lots of computers that automatically assign
IP addresses via DHCP, then you can also select 'DHCP on' so the panel can
get its network information automatically. This is possible on the panel, and it's
only ATEM Mini that always requires a fixed IP, as the switcher needs to be
found by the control panels at a known fixed address on your network.
ATEM Mini Pro is set to use DHCP by default, so if you are connecting an
ATEM hardware panel and ATEM Mini Pro to a network that supports DHCP,
you can set the panel to 'DHCP on' and your network settings will be
complete because the panel network settings will be obtained from the
network automatically.
Connecting to a Network
85