Field Settings Table - Rotex RKHBRD011AAV1 Manuel D'installation

Masquer les pouces Voir aussi pour RKHBRD011AAV1:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 123
The configuration of pattern B is done by field settings:
1
Select the appropriate pattern: [7-02] = 1
2
Turn on multiple set point 1: [7-03] = 0
Turn on multiple set point 2: [7-04] = 0
3
Enter the temperature multiple set point 1: [A-03] (see below)
Enter the temperature multiple set point 2: [A-04] (see below)
Configuration example:
Set
Field
point
setting
Space 0
65°C
Remote
controller
Space 1
45°C
[A-03]
Space 2
35°C
[A-04]
Resulting heat pump water
Pattern B can also be used to do some primary multi zoning (if all set
point temperatures are selected the same, no temperature reducing
device (
) is required).
Multiple thermo ON signals for 3 rooms can be generated. Thermo
OFF signals are only valid if all requests are OFF.

Field settings table

First
Second
code
code
Setting name
0
Remote control setup
00
User permission level
01
Room temperature compensation value
03
Status : space heating schedule timer mode
1
Automatic storage timing for domestic water heating
00
Status: night time storage
01
Night time storage start time
02
Status: day time storage
03
Day time storage start time
2
Automatic setback function
00
Status: setback operation
01
Setback operation start time
02
Setback operation stop time
3
Weather dependent set point
00
Low ambient temperature (Lo_A)
01
High ambient temperature (Hi_A)
02
Set point at low ambient temperature (Lo_Ti)
03
Set point at high ambient temperature (Hi_Ti)
4
Disinfection function
00
Status: disinfection operation
01
Disinfection operation day selection
02
Disinfection operation start time
5
Automatic setback and disinfection set point
00
Set point: disinfection operation temperature
01
Disinfection operation time duration
02
Leaving water setback temperature
03
Room setback temperature
6
Option setup
00
Domestic hot water tank installed
01
Optional room thermostat installed
04
Benefit kWh power supply mode
Installation manual
28
[7-03] = 1
[7-04] = 1
Thermo status
OFF
ON
OFF
OFF
OFF
OFF
ON/OFF ON
ON
OFF
OFF
ON/OFF OFF
ON
ON
OFF
65°C
45°C
45°C
35°C
Installer setting at variance with default value
Date
NOTE
Leaving water control is not allowed for pattern B.
It is the installers responsibility to make sure no
unwanted situations can occur (e.g. too high
water temperatures towards floor heating loops,
etc.).
It is the installers responsibility to make sure the
water circuit is well balanced (e.g. when a
domestic hot water request occurs, there will be
sufficient flow towards other appliances as well,
etc.)
Rotex does not offer any temperature reducing
device (
possibility to use multiple set points.
When space 0 is in thermo OFF, but space 1 or 2
are active, space 0 will be fed with water at a
temperature equal to the highest set point of
spaces 1 and 2.
This can lead to unwanted heating of space 0.
Value
Date
Value
). This system only provides the
Default
value
Range
Step
2
2~3
1
0
–5~5
0.5
1 (ON)
0/1
1 (ON)
0/1
1:00
0:00~23:00
1:00
0 (OFF)
0/1
15:00
0:00~23:00
1:00
1 (ON)
0/1
23:00
0:00~23:00
1:00
5:00
0:00~23:00
1:00
–10
–20~5
1
15
10~20
1
70
25~80
1
45
25~80
1
1 (ON)
0/1
Fri
Mon~Sun
23:00
0:00~23:00
1:00
70
60~70
5
10
5~60
5
5
0~10
1
18
17~23
1
0 (OFF)
0/1
0 (OFF)
0/1
0
0/2
1
RKHBRD011~016AAV1+Y1
Indoor unit for air to water heat pump system
4PW55786-1
Unit
°C
hour
hour
hour
hour
°C
°C
°C
°C
hour
°C
min
°C
°C

Publicité

Table des Matières
loading

Table des Matières