Replacing The Pump Seal - Orved Cuisson 31 Mode D'emploi Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

MAINTENANCE AND TEChNICAl SUPPORT
11.8 REPLACINg ThE PUMP SEAL
1) To access the pump, follow steps 3 to 9 in section 11.7.
2) Locate the pump intake block on which is fastened the tran-
sparent pipe with metal coil
vacuum chamber.
3) Use a hexagon wrench to undo the two screw fasteners on the
block. Lift the intake block (fig. 1).
4) Remove first the rubber seal and then the steel one. Check the
condition of the accessible intake section and clean it if necessary
with a cloth soaked in alcohol (fig. 2).
5) Put in the new rubber and steel seals (fig. 3).
6) Put the intake block back in place and fasten the two screws (fig. 1).
7) Reclose the appliance, following steps 16-19 in section 11.7.
74
Rev. 01 - 03/2018 - Cod. 1500024 - Instruction manual for vacuum chamber packaging machines for vacuum cooking mod.
A
that connects the pump to the
fig. 1
fig. 3
A
fig. 2
Cuisson

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cuisson 41Cuisson 41hCuisson 61

Table des Matières