Interpreting The Leds Of The Display; Maximum Programmable Values; Factory-Set Values; Visual Warnings - Orved Cuisson 31 Mode D'emploi Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

9.1.1 INTERPRETING ThE lEDS Of ThE DISPlAy

The six upper and lower LEDs provide an immediate graphical indication on
the current function, on the number of cycles performed before the oil must
be replaced, on the alarm status and on the value set in relation to the maxi-
mum value that can be set.

9.1.2 MAXIMUM PROGRAMMAblE VAlUES

fUNCTION
VACUUM
ADDITIONAl VACUUM
SEAlING
GAS INjECTION
WARNINGS!
• The difference between the value of the vacuum and the value of the gas must be 30%. Therefore, the ma-
ximum gas value that can be set – with a 99% vacuum value – is 69%
• The minimum sealing value is 1 second and therefore it cannot be reset.

9.1.3 fACTORy-SET VAlUES

The factory settings that appear upon the first start-up are described below. These values can be changed or integrated
via programming, in which case they are overwritten.
The factory settings can be restored at any time by resetting (§9.4.2 / pt.3)
Vacuum 99% - Additional vacuum (Plus Vacuum) 5 seconds – sealing 3.5 seconds.

9.2 VISUAl WARNINGS

The 12 LEDs and the two displays allow a number of useful messages relative to machine maintenance and safety to be
displayed (§ 9.1.1).
Upon the two displays, in addition to the functions inherent the performed working cycle, further more important in-
formation such as serial number, the number of cycles performed by the machine before changing the oil, the software
version installed displayed and/or can be recalled.
Rev. 01 - 03/2018 - Cod. 1500024 - Instruction manual for vacuum chamber packaging machines for vacuum cooking mod.
MIN-MAX SCAlE
30 - 99%
0 - 120 sec
1 - 9,9 sec
0 - 30%
OPERATION
Cuisson
43

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cuisson 41Cuisson 41hCuisson 61

Table des Matières