Connecting The Perimeter Wire - Viking MI 632 Manuel D'utilisation

Masquer les pouces Voir aussi pour MI 632:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Drive in the last fixing pin (1) on the left or
right next to the floor plate, directly next to
the wire outlet. Cut off the perimeter
wire (2). Provide free wire ends with a
length of approx. 1 m.
● Check the fastening of the perimeter
wire to the ground. One fixing pin per
meter is sufficient as a rough guide. The
perimeter wire must always lie on the
lawn. Drive the fixing pins fully into the
ground.
● After completing this installation
work, press the OK button on the
control panel.
If the battery is not sufficiently
charged to work through the
remaining steps of the installation
assistant, an appropriate message
is displayed. In this case, leave the
robotic mower in the docking
station to continue charging the
battery.
Jumping to the next step of the
installation assistant with the OK
button is only possible once the
necessary battery voltage is
available.

9.8 Connecting the perimeter wire

110
Place the robotic mower (1) within
the mowing area behind the docking
station (2) as shown, then press the
OK button.
Disconnect the power supply unit
plug from the mains, then press the
OK button.
Remove the cover as described in the
"Installing the docking station" section.
(
9.6)
Then press the OK button on the
control panel.