U-shaped mowing area with several free-
standing trees
Docking station:
Location (1) directly next to the house A
No-go areas:
Installation around the free-standing trees,
based on linking sections installed at right
angles to the edge (2), two no-go areas
are connected via a linking section.
Wire clearances: (
12.5)
Clearance to obstacles which can be
travelled on such as patios and paths:
0 cm
Clearance to the trees: 37 cm
Clearance to high obstacles: 27 cm
164
Programming:
No further adaptation is necessary
following definition of the size of the
mowing area.
Particulars:
Tree in the corner of the mowing area –
mow the area behind the blocked-off tree
regularly using a suitable lawn trimmer or
leave as a patch of high-grass.
0478 131 9933 A - EN