Viking MI 632 Manuel D'utilisation page 167

Masquer les pouces Voir aussi pour MI 632:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Divided mowing area with a pond and a
free-standing tree
Docking station:
Location (1) directly next to the house A
No-go area:
Installation around the free-standing tree,
based on a linking section installed at right
angles to the edge.
Pond:
Clearance from the perimeter wire (2) to
the pond B: 100 cm
Wire clearances: (
12.5)
Clearance to obstacles that can be
travelled on such as patios and paths:
0 cm
Clearance to high obstacles: 27 cm
Clearance around the tree: 37 cm
Clearance to the pond: 100 cm
0478 131 9933 A - EN
Confined area:
Installation of a corridor (3) (
Wire clearance: 27 cm
Search loops:
Installation of two search loops (4).
Minimum distance from the corridor
entrance: 2 m
Note the minimum clearance to corners.
(
12.11)
Programming:
Define the total size of the mowing area,
program two starting points (5) (close to
the docking station and in the contorted
corner near the pond) – starting frequency
2 of 10 operations in each case (
Points to note:
12.9)
Unmown areas, e.g. around the pond,
must be mown manually on a regular basis
or cut using a suitable lawn trimmer.
11.15)
165

Hide quick links:

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mi 632 pMi 632 cMi 632 pcImow mi 632Imow mi 632 pImow mi 632 c ... Afficher tout

Table des Matières