Connect the connector of the
power supply unit (1) to the
circuit board of the docking
station.
If necessary, the connector can be
removed (e.g. in order to route the
power cable through a hole in a
wall).
Make sure that the polarity is
correct when attaching the
connector to the power cable.
(
16.8)
Guide the power cable as shown through
the strain relief (1), through the cable
duct (2) and to the power supply unit.
● Install the power supply unit outside the
mowing area, protected from direct
sunlight, humidity and moisture – fasten
to a wall if necessary.
● Route all power cables outside the
mowing area, in particular out of
working range of the mowing blade, and
fasten them to the ground or
accommodate in a cable duct.
0478 131 9933 A - EN
● Unreel power cables in the vicinity of
the docking station in order to avoid
interference with the wire signal.
Correct operation of the power
supply unit is only ensured at an
operating temperature between
0° C and 60° C.
Fit the cover (1) onto the
docking station and allow it to
engage – do not pinch any
cables. Then connect the mains
plug.
The red LED on the docking station
flashes as long as no perimeter
wire is connected. (
● After completing this installation
work, press the OK button on the
control panel.
If an external docking station has
been installed, VIKING
recommends defining at least one
starting point outside the corridor to
the docking station after initial
installation is complete. The starting
frequency should be defined so that
0 of 10 mowing operations (0/10)
are started at the docking station
(starting point 0). (
Lift the robotic mower slightly by the carry
handle (1) to relieve the weight on the
drive wheels. Push the machine, resting
on its front wheels, into the docking
13.1)
station.
No LED must illuminate on the docking
station after docking. (
11.15)
13.1)
107