27. Installation examples

Rectangular mowing area with one tree
and swimming pool
Docking station:
Location (1) directly next to the house A
No-go area:
Installation around the free-standing
tree (3), based on a linking section
installed at right angles to the edge.
Swimming pool:
Distance between perimeter wire (2) and
pool B: 100 cm
Wire clearances: (
12.5)
Clearance to obstacles which can be
travelled on such as patios and paths:
0478 131 9933 A - EN
0 cm
Clearance to high obstacles: 27 cm
Clearance to the tree: 37 cm
Clearance to the pool: 100 cm
Programming:
No further adaptation is necessary
following definition of the size of the
mowing area.
Particulars:
Unmown areas around the swimming pool
must be mown manually on a regular basis
or cut using a suitable lawn trimmer.