Parameter Table - Parker AC30V Série Manuel Technique

Masquer les pouces Voir aussi pour AC30V Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

D-120
Parameter Reference

Parameter Table

This table is a complete list of all the parameters in the AC30V.
PNO:
The parameter number, a unique identifier for this parameter.
Name: The parameter's name as it appears on the GKP and web page.
Path(s): The navigation path(s) to this parameter on the GKP and web page.
Type:
The data type of the parameter.
Data Type
BOOL
A Boolean quantity representing FALSE or TRUE. (A zero value is FALSE).
SINT
A signed integer with a maximum range of -128 to +127.
INT
A signed integer with a maximum range of -32768 to +32767
DINT
A signed integer with a maximum range of -2147483648 to +2147483647
(1)
USINT
An unsigned integer with a maximum range of 0 to 255
UINT
An unsigned integer with a maximum range of 0 to 65535
UDINT
An unsigned integer with a maximum range of 0 to 4294967295
REAL
A 32-bit floating point conforming to IEEE-754
TIME
A duration with a resolution of 1 ms and a maximum range of 0.000s to 4294967.295s, (about 50 days)
DATE
Date with a maximum range of 1
TIME_OF_DAY
Time of day
DATE_AND_TIME Date and time of day with a maximum range of 1
STRING
String
BYTE
Bit string length 8
(2)
WORD
Bit string length 16
(2)
DWORD
Bit string length 32
(1) Some parameters of type USINT use discrete integer values to enumerate given states. For example; PNO 0001, the analog input hardware
configuration may be set to 0, 1, 2 or 3 corresponding to the supported ranges. Such parameters have the available selections shown in the
Range column.
(2) Some Bit string parameters have the individual bits within the word assigned independently to separate functionality. For example PNO 0005
presents the state of all digital inputs in one 16-bit word. The bits may be individually accessed on the GKP and webpage by expanding the
parameter. Each individual feature may be accessed as a Boolean via any fieldbus communications link by referencing the dedicated PNO.
Default: The default value of the parameter.
Range: The minimum and maximum values for this parameter. This column is also used to detail the available selection for enumerated integer
types and named bits in bit string data types.
Units:
The units text displayed with this parameter value.
Description
st
Jan 1970 to 2037.
st
Jan 1970 to 2037
AC30V series Variable Speed Drive

Publicité

Table des Matières
loading

Table des Matières