D-102
Parameter Reference
Spd Loop Diagnostics
Parameters::Motor Control::Spd Loop Diagnostics
Refer to the diagram in Spd Loop
Only applies to SVC control mode, IM or PMAC.
PNO
Parameter Descriptions
0533
Total Spd Demand RPM
This diagnostic shows the final values of the speed demand in rpm obtained after summing all sources. This is the value which is
presented to the speed loop
0534
Total Spd Demand %
This diagnostic shows the final values of the speed demand as a % of 100% Speed in RPM of the Scale Setpoint obtained after
summing all sources. This is the value which is presented to the speed loop.
0535
Speed Loop Error
This diagnostic shows the difference between the total speed demand and the speed feedback
0536
Speed PI Output
This diagnostic shows the torque demand due to the speed loop PI output, not including any feedforward terms.