Les langues disponibles

Slip Compensation
Parameters::Motor Control::Slip Compensation
Designed for VOLTS/Hz motor Control Mode.
The slip compensation function allows the Drive to maintain motor speed in the presence of increased load.
PNO
Parameter Descriptions
0354
Slip Compensatn Enable
Enable/Disable slip compensation
0356
SLP Motoring Limit
Maximum compensated speed in motor control
0357
SLP Regen Limit
Maximum compensated speed in regen mode
Functional Description
Based on the rated speed, the no load speed and the rated load of the motor, the Slip Compensation feature adjusts the demand frequency to
compensate for any speed reduction resulting from the load.