Torque Limit
Parameters::Motor Control::Torque Limit
This function allows you to set the maximum level of motor rated torque which is allowed before torque limit action occurs.
If the estimated motor torque is greater than the Actual Pos Torque Lim value, the motor speed is controlled to maintain the torque at this level.
A similar situation occurs if the estimated motor torque is less than the Actual Neg Torque Lim value.
The torque limit function has separate positive and negative torque limits. In addition, a symmetric main torque limit is also provided.
The lowest positive and negative torque limits (including any current limit or inverse time current limit action) is indicated in the Actual Pos
Torque Lim and Actual Neg Torque Lim diagnostic. These values determine the absolute motor torque limits.
PNO
Parameter Descriptions
0415
Positive Torque Lim
This parameter sets the maximum allowed level of positive motor torque.
0416
Negative Torque Lim
This parameter sets the maximum allowed level of negative motor torque
0417
Main Torque Lim
This parameter sets the symmetric limit on the maximum allowed motor torque.
0418
Fast Stop Torque Lim
This parameter sets the torque limit used during a Quickstop.
0419
Symmetric Torque Lim
When TRUE, the Negative Torque Lim is forced to reflect the Positive Torque Lim parameter.
0420
Actual Pos Torque Lim
This diagnostic indicates the final actual positive torque limit including any current limit or inverse time current limit action.
0421
Actual Neg Torque Lim
This diagnostic indicates the final actual negative torque limit including any current limit or inverse time current limit action.
AC30V series Variable Speed Drive
D-111
Parameter Reference