Energy Meter

Monitor::Energy Meter
Parameters::Motor Control::Energy Meter
This feature measures the electrical energy used by the motor.
PNO
Parameter Descriptions
0380
Power kW
This diagnostic shows the power being delivered to the load in kilowatts.
0381
Power HP
This diagnostic shows the power being delivered to the load in horsepower.
0382
Reactive Power
This diagnostic shows the reactive power being delivered to the load in kilo volt-amperes reactive.
0383
Energy kWh
This diagnostic shows the total energy consumed by the load in kilowatt hours.
0385
Power Factor Est
This diagnostic shows the power factor estimate (between 0 and 1).
0386
Power Factor Angle Est
This diagnostic shows the power factor angle estimate.
0389
Reset Energy Meter
When Reset Energy Meter is set to TRUE, the Energy KWh parameter is reset to zero automatically when the maximum value is
reached.
When Reset Energy Meter is set to FALSE, the Energy KWh parameter is held at the maximum value when the maximum value
has been reached
Changing this from FALSE to TRUE at anytime will cause the Energy KWh parameter to be reset to zero.