Parker AC30V Série Manuel Technique page 316

Masquer les pouces Voir aussi pour AC30V Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

D-90
Parameter Reference
Scale Setpoint
Parameters::Motor Control::Scale Setpoint
This function defines 100% speed in RPM.
PNO
Parameter Descriptions
0464
100% Speed in RPM
Maximum rpm set by the user
Functional Description
The Drive is commanded to run the motor at a certain speed, which is derived from various sources, such as comms, analog inputs, commands
from the keypad, etc. All these speed commands are expressed as a percentage. The percentage is referenced to this parameter. So, for
example, if this parameter is set to 3000 rpm, and the user commands 100% speed, then the motor should turn at 3000rpm.
However, the user must be aware of what this parameter means for different control options:
-
For vector control (both for PMAC and IM) for 100% demand the motor will provide the actual shaft speed of the value that is set in this
parameter.
-
For V/Hz control (IM only) for 100% demand the actual shaft speed will be the value set in this parameter less than the slip of the motor.
So, in order to achieve rated speed at rated torque in V/Hz mode, the user should put in this parameter an RPM value that is
corresponding to the base frequency of the motor with the number of pole pairs taken into account, or in other words, '100% Speed in
RPM' should be set to synchronous speed. (For example, a 50Hz, 4 pole induction motor, with rated speed of 1450RPM, should have its
'100% Speed in RPM' value set to 1500. This will ensure that in V/Hz mode when the motor is loaded with rated load the actual speed of
the shaft will be 1450 RPM!)
This parameter also represents the maximum speed available, since (apart from a small allowance for process trims) the speed commands are
not allowed to exceed 100%.